BRAT

Step 7 - Summary Report (Optional)

Creating a Summary Report (Optional)

After running the BRAT tool, it can sometimes be useful calculate additional metrics on the output. The Summary Report tool adds and calculates a number of fields that further contextualize the results of a BRAT run.

Running the Tool

Running the tool is fairly simple. The tool takes three inputs:

  • The Conservation Restoration Model output network
  • An optional shapefile containing points that correspond to observed beaver dams
  • The name of the output If not given a beaver dam shapefile, the tool will not produce the fields that rely on dams data. Be warned, the tool will snap the points of the beaver dam shapefile to the nearest reach, which will change the file given to it. If you want to retain the original position of the beaver dams, give the tool a copy of your shapefile.

Output of the Tool

The tool produces eight new fields. Three of these fields are reliant on the dams input. The fields are as follows:

  • e_DamCt: The observed number of dams per segment (based on the beaver dam shape file).
  • e_DamDens: The number of dams per kilometer. Calculated by dividing e_DamCt by the segment length.
  • e_DamPcC: The ratio between the observed dam count and the calculated existing capacity. Calculated by dividing e_DamCt by oCC_EX.
  • Ex_Categor: The category of the calculated existing capacity. It is determined based on the oCC_EX (the calculated existing capacity), as follows:
    • If oCC_EX = 0, Ex_Categor = “None”
    • If 0 < oCC_EX <= 1, Ex_Categor = “Rare”
    • If 1 < oCC_EX <= 5, Ex_Categor = “Occasional”
    • If 5 < oCC_EX <= 15, Ex_Categor = “Frequent”
    • If 15 < oCC_EX, Ex_Categor = “Pervasive”
  • Pt_Categor: The category of the calculated potential capacity. It is determined based on the oCC_PT (the calculated potential capacity), as follows:
    • If oCC_PT = 0, Pt_Categor = “None”
    • If 0 < oCC_PT <= 1, Pt_Categor = “Rare”
    • If 1 < oCC_PT <= 5, Pt_Categor = “Occasional”
    • If 5 < oCC_PT <= 15, Pt_Categor = “Frequent”
    • If 15 < oCC_PT, Pt_Categor = “Pervasive”
  • mCC_EX_Ct: The existing capacity density. Calculated by dividing oCC_EX by the segment length.
  • mCC_PT_Ct: The potential capacity density. Calculated by dividing oCC_PT by the segment length.
  • mCC_EXtoPT: The ration between existing and potential capacity. Calculated by dividing oCC_EX by oCC_PT.

Caveats

Currently the Summary Report tool is limited by the distance and relation that dam capture events to the NHD line. This can result in short reaches being assigned multiple dams and having overestimated dam densities due to the small reach length. While larger reaches adjacent to the short reach which might have been assigned some of the dams are not and have low dam densities.

Original validation issue

To remedy this BRAT has integrated multichannel line segments from the original nhd file that warrent the classification of a perennial network. BRAT was previously not able to handle multichannel features. This has not fixed all these cases but many of them, because these slower flows in multichannel clusters can result in refuge from high streampower which can results in blown out or breached dams.

Multichannel/Anabranch incorporated into the model

Back to Step 6 Continue to Step 8

Back to Help Back to BRAT Home